Your printer requires a properly grounded AC outlet with a rated line voltage of 100
V, 120 V, or 220/240 V.
The line voltage must remain within ±10 percent of the rated voltage for proper
operation of the printer.
The amperage capacity of the electrical outlet must be at least 1.2 times that used
by the printer.
The maximum electrical current required during operation is 10 amps for a 100 V
system, 8.3 amps for a 120 V system, and 4.5 amps for a 220/240 V system.
Noise-generating equipment should not be connected to the same electrical outlet
as the printer.
The recommended frequency is 50–60 Hz ±2 Hz for a 100 V system, 60 Hz ±2 Hz
for a 120 V system, and 50 Hz ±2 Hz for a 220/240 V system.


Printer performance depends upon the type of computer to which you connect it. We
recommend a Pentium-class computer with at least 16 MB of RAM (if you’re using
Windows 95/98) or 32 MB of RAM (if you’re using Windows NT 4.0).
The QMS
magicolor
2 DeskLaser is compliant
with US Environmental Protection Agency (EPA)
Energy Star regulations. After a specified period
of inactivity, the printer changes to a low-power
state (the engine remains on, but the fuser turns
off). When a print job is received, the printer
returns to normal power within a user-config-
urable time period.